OEM Ec Meter E; Ectriv Conductivity Sensor
Product Description
PCEC01 Online Conductivity/Resistivity Controller
Product overview
PCEC01 EC online analyzer is an intelligent online chemical analyzer. The cap of the sensor is coated with a luminescent material. Blue light from an LED illuminates the luminescent chemical. The luminescent chemical instantly becomes excited and releases red light. The time and intensity of red light are inversely proportional to the concentration of oxygen molecules, So the concentration of oxygen molecules is calculated.
Features
Support dissolved oxygen(DO), saturation(SAT), oxygen partial pressure(OPP) and temperature measure.
Support upper/lower limit control, transmitting output, RS485 communication.
Configurable manual and auto temperature offset function.
Configurable upper/lower limit alarm and delay.
Configurable hummer and LCD backlight switch.
Optional language, Chinese and English.
Zero oxygen and full-scale calibration.
Applications
Sewage treatment plants:
Oxygen measurement and regulation in the activated sludge basin for a highly efficient biological cleaning process
Environmental protection water monitoring:
Oxygen measurement in rivers, lakes or seas as an indicator of the water quality
Water treatment:
Oxygen measurement for status monitoring of drinking water for example (oxygen enrichment, corrosion protection etc.)
Fish farming:
Oxygen measurement and regulation for optimum living and growth conditions
Measuring principle |
• Sensor design:
- Oxygen-sensitive molecules (markers) are integrated in an optically active layer (fluorescence layer).
- The surface of the fluorescence layer is in contact with the medium.
- The sensor optics are directed at the underside of the fluorescence layer.
• There is an equilibrium between the oxygen partial pressure in the medium and that in the fluorescence layer:
- If the sensor is immersed in the medium, the equilibrium is established very quickly.
• Measuring process:
- The sensor optics send green light pulses to the fluorescence layer.
- The Oxygen-sensitive molecules instantly becomes excited and releases red light.
- The duration and intensity of the response signals is directly dependent on the oxygen contents and the partial pressure.
- If the medium is free from oxygen, the response signals are long and very intense.
- Oxygen molecules quench the Oxygen-sensitive molecules. As a result, the response signals are shorter and less intense.
• Measurement result:
- The sensor returns a signal that is in proportion to the oxygen concentration in the medium.
- The medium temperature and air pressure are already taken into account calculated in the sensor.
- In addition to the standard values of concentration, saturation index and partial pressure,
the sensor also returns a raw measured value in μs. The value corresponds to the decay time of the fluorescence and is approx. 20 μs in air and approx. 60 μs in media free from oxygen.
Technical specifications | |||
Measurement variables | Dissolved oxygen, saturation, oxygen partial pressure | ||
Measuring range | 0 - 20mg/L,0 - 200%,0 - 400hPa | ||
Resolution | 0.01mg/L,0.1%,1hPa | ||
Accuracy | ±1.5%FS | ||
Repetition | ±0.5%FS | ||
Temperature measurement type | NTC 10K/PT1000 | ||
Auto A/manual H Measuring range | -10 - 60ºC Resolution: 0.1ºC Correction accuracy: ±0.5ºC | ||
Output type 1 | 4 - 20mA current transmission output | ||
Max.loop resistance | 750Ω | ||
Current Output Accuracy | 0.1%FS | ||
Output type 2 | RS485 digital signal output | ||
Communication protocol | Standard MODBUS-RTU (customizable) | ||
Power supply | AC220V±10%, 50Hz/60Hz (optional 24V±10%) | ||
Alarm relay | AC250V, 3A |
Installation method |
2 Dissolved oxygen sensor
Identification of terminal |
Wiring diagram
+12VDC: Power supply of dissolved oxygen electrode
AGND: Power negative of dissolved oxygen electrode
RS485-A: Dissolved oxygen electrode communication-A
RS485-B: Dissolved oxygen electrode communication-B
NC: Null
RS485(A+): RS485 communication interface A+
Optical Dissolved Oxygen Online Analyzer - Operation Manual
RS485(B-): RS485 communication interface B-
I(+):4-20mA output port +
I(-): 4-20mA output port -
HO: High alarm of normal open relay
HC: High alarm of normal close relay
COM: Common port
LO: Low alarm of normal open relay
LC: Low alarm of normal close relay
COM: Common port
220V L: AC220V fire wire
NC: Null
220V N: AC220V zero wire
About us:
Exhibitions:
Certifications
Product Categories : Water analyzer
Premium Related Products
Other Products
Hot Products
GPRS wireless pressure measuring instruments HPT800-WRS485 Smart Digital Water Tank Radar Level GaugeHPT300-S3 4 20mA 0 5V ambient pressure transmitter with angular connector good quality and priceOil level tanke level gauge Holykell Wholesale products oil tank fuel level gaugeHPT604 4-20mA 24vdc 316 stainless steel diesel fuel oil tank level gauge sensorHolykell HPT604 stainless steel RS485 PTFE cable gasoline level sensorSubmersible 12VDC RS485 4-20mA 0-5V water level sensorTemperature Humidity Control Display ChannelsHPT300-C air compressor pressure sensor for HVAC systemsceramic pressure sensor for brake system, air compressor and oil compressorHPT601 Holykell Level Measuring Instruments for Drinking Water and Milk and TankHigh Temperature Boiler Water Pressure Sensor Transducer HPT200-HT HolykellCaterpillar Water Temperature Sensor Gas Water Heater Temperature Sensor 23518092UE3005 0-5M ultrasonic sensors measuring level of liquidsUE3005 0-2M high quality ultrasonic fuel level sensor 4-20maRS485 Flowmeter Modbus Diesel Flow Meter